STRUCTURAL REPAIR BY EXTERNAL PRESTRESSED CABLES TECHNOLOGY, IN ADDITION TO COMPOSITE CFRP

Sunday - 25/07/2021 11:43
STRUCTURAL REPAIR BY  EXTERNAL PRESTRESSED CABLES TECHNOLOGY, IN ADDITION TO COMPOSITE CFRP
PROJECT: STRUCTURAL REINFORCEMENT WITH EXTERNAL PRESTRESSED CABLES AND CFRP.
INVESTOR: PHU TAI JOINT STOCK COMPANY
EXECUTING UNIT: BKG JOINT STOCK COMPANY



Structural reinforcement by external prestressed cables technology combined with CFRP composite material is effective in lifting the floor load from 250 Kg/m2 up to 600 Kg/m2. During the tensioning process, the structural monitoring system is used to monitor the construction process to achieve the highest safety and efficiency.
 
Mô hình thí nghiệm DUL ngoài
Experimental model in the room about the external prestressed cables

Mô hình tính toán Sap2000 bản quyền
Copyrighted SAP2000 calculation model
 
f36456e48e02695c3013
Drill holes to create holes in beams, floors
 
87e1ee1836fed1a088ef
Install the bearing to the design position
 
8b49de99077fe021b96e
Insert the external prestressed cables into the tension position
 
703b3741f9521d0c4443
Carrying out tensioning of external prestressed cables 
cde83decd8ef3cb165fe
Structural monitoring system during tensioning external prestressed cables
 
dbc80756deb039ee60a1
Underfloor CFRP reinforcement
 
d67076a9af4f4811115e
CFRP reinforcement on the floor

After the structural reinforcement repair was completed, the testing unit of the Center for Science, Technology & Investment Consulting, Da Nang University of Science and Technology performed the load test to re-evaluate the load carrying capacity of the structure.
 
dc5a31b89def7ab123fe
Use water to pump into the load test cell
 
64fb20038c546b0a3245
Load to design
 
41
Installation of stress equipment
 
40
Install displacement LVDT device
 
ae6b12e6beb159ef00a0
Connect the device to the control center
 
99ccf1505d07ba59e316
Conduct data collection
 
38
Automatic data collection
After carrying out the load test within 24 hours, the load test results were obtained with the design requirements for reinforcement from 250Kg/m2 up to 600 Kg/m2.





 